PRODUCT
product description
▾
For Export
Husteon Mesh is a "class 4 medical device" used to repair craniofacial defected area.
It is a material with excellent biocompatibility which has less inflammatory reaction after implantation, and smoothly facilitates cell or nutrient exchange with surrounding tissues in the body.
After transplantation, when certain period of time pass by, it induces the production of extracellular matrix, such as collagen, and contributes to the reconstruction of damaged tissues.
Afterwards, since the high polymer PCL is finally decomposed into carbon dioxide (CO2) and water (H2O) by hydrolysis and released outside the body, the second operation for removal is not necessary.
Husteon is produced using a 3D printer at the internal clean room according to GMP standards, and has various sizes and strengths which can be selectively used for defective areas.
✔ Inserted into the craniofacial defected area
✔ Available in various sizes depending on the defected area
✔ No need for second operation since it biodegrades in 2-3 years
![]() |
Example of Application |
Husteon Mesh is a "class 4 medical device" used to repair craniofacial defected area.
It is a material with excellent biocompatibility which has less inflammatory reaction after implantation,
and smoothly facilitates cell or nutrient exchange with surrounding tissues in the body.
After transplantation, when certain period of time pass by, it induces the production of extracellular matrix, such as collagen,
and contributes to the reconstruction of damaged tissues.
Afterwards, since the high polymer PCL is finally decomposed into carbon dioxide (CO2) and water (H2O) by hydrolysis and
released outside the body, the second operation for removal is not necessary.
![]() | Husteon is produced using a 3D printer at the internal clean room according to GMP standards, and has various sizes and strengths which can be selectively used for defective areas. |
![]()
| ✔ Inserted into the craniofacial defected area ✔ Available in various sizes depending on the defected area ✔ No need for second operation since it biodegrades in 2-3 years |
NO. | Model | Size | ||||
Regular | Stiff | Super Stiffness | A | B | C | |
1 | HM015-2015 | - | - | 20 | 15 | 0.15 |
2 | HM020-2015 | - | - | 20 | 15 | 0.2 |
3 | HM030-2015 | - | HMSS030-2015 | 20 | 15 | 0.3 |
4 | HM050-3010 | HMS050-3010 | HMSS050-3010 | 30 | 10 | 0.5 |
5 | HM080-3010 | HMS080-3010 | HMSS080-3010 | 30 | 10 | 0.8 |
6 | HM100-3010 | HMS100-3010 | HMSS100-3010 | 30 | 10 | 1.0 |
7 | HM015-3020 | - | - | 30 | 20 | 0.15 |
8 | HM020-3020 | - | - | 30 | 20 | 0.2 |
9 | HM030-3020 | - | HMSS030-3020 | 30 | 20 | 0.3 |
10 | HM050-3020 | HMS050-3020 | HMSS050-3020 | 30 | 20 | 0.5 |
11 | HM050-4010 | HMS050-4010 | HMSS050-4010 | 40 | 10 | 0.5 |
12 | HM080-4010 | HMS080-4010 | HMSS080-4010 | 40 | 10 | 0.8 |
13 | HM100-4010 | HMS100-4010 | HMSS100-4010 | 40 | 10 | 1.0 |
14 | HM015-4030 | - | - | 40 | 30 | 0.15 |
15 | HM020-4030 | - | - | 40 | 30 | 0.2 |
16 | HM030-4030 | - | HMSS030-4030 | 40 | 30 | 0.3 |
17 | HM050-5050 | HMS050-5050 | HMSS050-5050 | 50 | 50 | 0.5 |
18 | HM080-5050 | HMS080-5050 | HMSS080-5050 | 50 | 50 | 0.8 |
19 | HM100-5050 | HMS100-5050 | HMSS100-5050 | 50 | 50 | 1.0 |
20 | HM100-7060 | HMS100-7060 | HMSS100-7060 | 70 | 60 | 1.0 |
INFORMATION
Company MediFab Co., Ltd
License No. 581-88-00448
TEL +82-02-2181-3658
FAX +82-02-2181-3659
E-mail sales-@imedifab.com
LOCATION
#417, Daeryung Techno Town 20th, 5, Gasan digital 1-ro,
Geumcheon-gu, seoul, Korea (08594)